Technical Information

Contact Details

Derek Schesnuk, Event Manager
dschesnuk@canaltacentre.com

Bret Jenkins, Director Operations
bjenkins@canaltacentre.com

Forklifts: 2 x 6000 lbs
Operated by: Canalta Centre / Patman Productions Inc.
Barricade: StageRight CC-500. Total 88′ (in 4′ sections)
Bicycle Rack: 400′ (in 8′ sections) Galvanized
Spotlights: 5 x Lycian 1290 XLT
Location: 4 located at the top of the Upper Bowl / 1 located in Catwalk (Southside)
Com Type: RTS 2 Wire / 4 Channel Party Line System
Pipe & Drape: In house – upon request

Star Dressing Room 1 – 23′ x 13′ w/ private shower, private bathroom, television, furnished
Star Dressing Room 2 – 22′ x 10′ w/ private shower, private bathroom, television, furnished
Dressing Room 1 – 22′ x 18′ (Locker room style)
Dressing Room 2 – 22′ x 18′ (Locker room style)
Dressing Room 3 – 22′ x 18′ (Locker room style)
Dressing Room 4 – 22′ x 18′ (Locker room style)

Notes:
– Dressing Rooms 1 & 2 / 3 & 4 are attached to one another and can be opened to make a larger area
– Additional furnishings available
– Each Dressing Room has phone and Internet capabilities

Floor Width: 85′
Floor Depth: 200′ w/ boards in (Hockey set-up) / 230′ full bleacher retraction
Floor Surface: Concrete (Summer Season) or Ice Decking – Space Age Synthetics (Hockey Season)
Dashers: removable at the East end + West end vomitories + AUX vomitory stairwells

Capacities: various capacities
Full Stage Bowl
3/4 Bowl Set-Up
1/2 Bowl Set-Up
Theatre Set-Up
Banquet Style Set-Up

All capacities depend on set-up and approval by the Medicine Hat Fire Department.

Supplied by: Patman Productions Inc. (Non Union)

Area: Loading Docks / Bay located on the East side of the building off of Box Springs Link NW
Event Floor Entrance: 14′ w x 16′ h
Docks/ Bay: 3 Trucks can be loaded/unloaded at one time
2 Loading Docks (w/ dock leveller – 100ft Ramp at 6% to 2% Grade)
1 Loading Bay
Push Distance to Event Floor: 60′ push from Dock / Bay to Event Floor
Fire Lane Required: 6′ Minimum on Stage Left / Right – determined by event set-up
Case Storage Areas: Storage areas available – adjacent to loading area – limited area available in hallways due to Fire Exits

Notes:
– Security Check point located in this area

Services available: All power 120/208 3 ph 5 wire
Upstage Left: 2 x 200 amp / 2 x 400 amp
Upstage RIght: 1 x 100 amp / 2 x 200amp / 2 x 400 amp
Additional Powers (Bus Parking / Loading Area): 2 x 30 amp / 5 x 50 amp / 1 x 60 amp / 1 x 100 amp / 4 x 200 amp

Floor to High Steel: No Rigging from High Steel
Floor to Low Steel- Rigging Grid: 54′ and 55′ – the Building is built on an incline / Roof is on an angle / Rigging grid built into 2 sections (54′ and 55′) – Rigging Load Manual available upon request
Venue Rigging Map: available upon request. End Stage: 120,000 lbs / Center Stage: 70,000 lbs
Rigging Obstructions: Scoreboard at the centre of the building – sits at 43′ when retracted
Riggers provided by Patman Productions Inc.

Notes:
– 
Hard Hats REQUIRED until Rigging / Trusses are in the air

Max Trim Height: 43′ fully retracted
Dimensions: 26′ x 26′ x 18′ h

Stage Type: Stage Right
108 pieces of 4′ x 8′ decking. Reversible Blk Tech Stage / Carpet
Stage Height: adjustable from 4′ to 6′
Riser Height: 
adjustable from 1.5′ to 2′
Stairs: 
4 sets of adjustable EZ lift stairs
Skirting Available: 
Yes
Fire Aisle: 
6′ minimum on Stage Left / Right – determined by event set-up
Distance off of Back Wall: 
8′ at the center of the curve – determined by event set-up